N707AU/ST BALANCED MAGNETIC SWITCH LEVEL 2

DESCRIPTION Nascom’s High Security UL Level 2 BMS, patent pending design utilizes multiple magnetic fields; providing the most advanced magnetic high security switch in the world. Applications include government facilities, bank safes and vaults.

FEATURES • SMALL FOOTPRINT

• ANODIZED ALUMINUM SWITCH AND MAGNET HOUSING • EPOXY ENCAPSULATED HERMETICALLY SEALED CONTACTS

• DOUBLE RESISTANT TAMPER

• UNIVERSAL MOUNT - LEFT OR RIGHT • 24” ARMORED CABLE (STANDARD)

• LISTED TO UL634 STANDARD

• SUITABLE FOR INDOOR OR OUTDOOR USE

SPECIFICATIONS

PARAMETERS

CONDITION

MIN TYP MAX UNITS

CONTACT RATINGS — ALARM CIRCUIT Operate Gap Release Gap Side-to-side offset

0.000 0.125

0.125 0.150 0.125 0.625 0.750 30 0.020 0.020 0.600

inches Inches Inches Inches Inches VDC Amps Amps VA Ops mOhms Inches Inches VDC Amps Amps VA Ops mOhms

Front-to-back offset Operate Front-to-back offset Release

Switching Voltage Switching Current

Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive 1V, 10mA Signal Level 50mV, 10mA

Carry Current Contact Rating Life Expectancy Static Contact Resistance Contact Material

1.00E+06

400

Au

CONTACT RATINGS — TAMPER CIRCUIT Operate Gap Release Gap

0.000

0.125 0.093 30 0.020 0.020 0.600

With spaces under switch and magnet Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive 1V, 10mA Signal Level 50mV, 10mA

Switching Voltage Switching Current

Carry Current Contact Rating Life Expectancy Static Contact Resistance Contact Material CIRCUIT INFORMATION Alarm Circuit Tamper Circuit SWITCH SPECIFICATIONS Insulation Resistance Capacitance Dielectric Strength ENVIRONMENTAL RATINGS Storage Temperature Operating Temperature

1.00E+06

400

Au

Closed Loop / Normally Open Closed Loop / Normally Open

100V, 25 o C, 40% RH Across Open Contacts Between Contacts

1.00E+09 250

Ohms VDC/PeakAC

-35 -35

+66 +66

o C o C

Royne Industries LLC, dba Nascom | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 12009-15 Rev. 3

N707AU/ST BALANCED MAGNETIC SWITCH LEVEL 2

WIRING SCHEMATIC

DIMENSIONS - IN [mm]

Royne Industries LLC, dba Nascom | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 12009-15 Rev. 3

N707AU/ST BALANCED MAGNETIC SWITCH LEVEL 2

ORDERING INFORMATION PART NUMBER

DESCRIPTION

N707AU/ST N707AU/STATS N707AU/SW N707AU/SWATS N707AU/M N707AUSPKIT N707AU/STR1xx N707AU/STR1xxR2xx N707AU/STR3 N707AU/STR3xxR4xx N707AU/STR1xxR3xxR4xx

Switch and e-strike magnet set Switch and e-strike magnet set with alarm and tamper circuits connected in series Switch only Switch with alarm and tamper circuits connected in series E-strike magnet only Spacer kit Switch and e-strike magnet set with alarm circuit resistor in series — xx=resistor value Switch and e-strike magnet set with alarm circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value Switch and e-strike magnet set with tamper circuit resistor in series — xx=resistor value Switch and e-strike magnet set with tamper circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value Switch and e-strike magnet set with alarm circuit resistor in series and tamper circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value Switch and e-strike magnet set with alarm circuit R1 resistor in series and R2 resistor in parallel and tamper circuit resistor in series — xx=resistor value Switch and e-strike magnet set with alarm and tamper circuits resistor in series — xx=resistor value Switch and e-strike magnet set with alarm and tamper circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value

N707AU/STR1xxR2xxR3xx

N707AU/STR1xxR3xx N707AU/STR1xxR2xxR3xxR4xx

EXAMPLE:

N707AU E=Strike set with alarm circuit 1K resistor in series, 1K resistor in parallel, and tamper circuit 1K resistor in series, 1 K resistor in parallel

N707AU/STR11KR21KR31KR41K

WOOD DOORS — NON FERROUS APPLICATIONS: Mount in desired location and orientation using #6 pan-head screws with a minimum recommended length of 1/2 inch. To ensure the highest security, keep the gap as small as practical. A 1/32” gap is recommended but the switch will operate at a maximum 1/8” gap. The flexible cable may exit the switch from either the left of the right side by removing the two #4 flathead machine screws located on the base of the switch and flipping the switch 180°. Refasten the screws but DO NOT OVERTIGHTEN THE SCREWS. After the switch and magnet have been mounted, remove the SWITCH BASE and temporarily mount the TAMPER INSERT, using the same #6 screws, in the same location that was used to mount the SWITCH BASE. Permanently mount the TAMPER INSERT using a third #6 screw in the location shown in the drawing. Remove the SWITCH BASE mounting screws and re-install the switch base over the TAMPER INSERT. The tamper circuit will alarm before the switch can be removed. STEEL DOOR AND FERROUS SURFACE APPLICATIONS : When mounting the switch and magnet on ferrous surfaces such as steel doors and safes, follow the above installation instructions, but you must also install the enclosed 1/4” thick spaces under the switch and magnet to achieve a 1/8” operate gap. Use #6 screws (stainless steel recommended) with a minimum recommended length of 1-1/2”. Use Spacer Kit (part number: N707AUSPKIT) for installation on offset surfaces to achieve correct alignment. INSTALLATION INSTRUCTIONS This level 2 BMS is to be connected / used with UL Listed Burglar Panels / Systems, Switch and Magnet must be aligned for corrrect operation!

Royne Industries LLC, dba Nascom | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 12009-15 Rev. 3

N707AU/STE BALANCED MAGNETIC SWITCH LEVEL 2 – ELECTRIC DOOR STRIKE

DESCRIPTION Nascom’s High Security UL Level 2 BMS, patent pending design utilizes multiple magnetic fields; providing the most advanced magnetic high security switch in the world. Applications include government facilities, bank safes and vaults. The N707AU/STE Model BMS prevents false alarms on doors with electric door strikes; maintaining the door in a secure state while allowing some lim- ited movement of the door in the latched position.

FEATURES • SMALL FOOTPRINT

• ANODIZED ALUMINUM SWITCH AND MAGNET HOUSING • EPOXY ENCAPSULATED HERMETICALLY SEALED CONTACTS

• DOUBLE RESISTANT TAMPER

• UNIVERSAL MOUNT - LEFT OR RIGHT • 24” ARMORED CABLE (STANDARD)

• LISTED TO UL634 STANDARD

• SUITABLE FOR INDOOR OR OUTDOOR USE

SPECIFICATIONS

PARAMETERS

CONDITION

MIN TYP MAX UNITS

CONTACT RATINGS — ALARM CIRCUIT Operate Gap Release Gap Side-to-side offset

0.000 0.125

0.125 0.150 0.125 0.625 0.750 30 0.020 0.020 0.600

inches Inches Inches Inches Inches VDC Amps Amps VA Ops mOhms Inches Inches VDC Amps Amps VA Ops mOhms

Front-to-back offset Operate Front-to-back offset Release

Switching Voltage Switching Current

Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive 1V, 10mA Signal Level 50mV, 10mA

Carry Current Contact Rating Life Expectancy Static Contact Resistance Contact Material

1.00E+06

400

Au

CONTACT RATINGS — TAMPER CIRCUIT Operate Gap Release Gap

0.000

0.125 0.093 30 0.020 0.020 0.600

With spaces under switch and magnet Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive Max DC/Peak AC Resistive 1V, 10mA Signal Level 50mV, 10mA

Switching Voltage Switching Current

Carry Current Contact Rating Life Expectancy Static Contact Resistance Contact Material CIRCUIT INFORMATION Alarm Circuit Tamper Circuit SWITCH SPECIFICATIONS Insulation Resistance Capacitance Dielectric Strength ENVIRONMENTAL RATINGS Storage Temperature Operating Temperature

1.00E+06

400

Au

Closed Loop / Normally Open Closed Loop / Normally Open

100V, 25 o C, 40% RH Across Open Contacts Between Contacts

1.00E+09 250

Ohms VDC/PeakAC

-35 -35

+66 +66

o C o C

Royne Industries LLC, dba Nascom | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 12009-15 Rev. 3

N707AU/STE BALANCED MAGNETIC SWITCH LEVEL 2 – ELECTRIC DOOR STRIKE

WIRING SCHEMATIC

DIMENSIONS - IN [mm]

Royne Industries LLC, dba Nascom | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 12009-15 Rev. 3

N707AU/STE BALANCED MAGNETIC SWITCH LEVEL 2 – ELECTRIC DOOR STRIKE

ORDERING INFORMATION PART NUMBER

DESCRIPTION

N707AU/STE N707AU/STEATS N707AU/SWE N707AU/SWEATS N707AU/ME N707AUSPKIT N707AU/STER1xx N707AU/STER1xxR2xx N707AU/STER3 N707AU/STER3xxR4xx N707AU/STER1xxR3xxR4xx

Switch and e-strike magnet set Switch and e-strike magnet set with alarm and tamper circuits connected in series Switch only Switch with alarm and tamper circuits connected in series E-strike magnet only Spacer kit Switch and e-strike magnet set with alarm circuit resistor in series — xx=resistor value Switch and e-strike magnet set with alarm circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value Switch and e-strike magnet set with tamper circuit resistor in series — xx=resistor value Switch and e-strike magnet set with tamper circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value Switch and e-strike magnet set with alarm circuit resistor in series and tamper circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value Switch and e-strike magnet set with alarm circuit R1 resistor in series and R2 resistor in parallel and tamper circuit resistor in series — xx=resistor value Switch and e-strike magnet set with alarm and tamper circuits resistor in series — xx=resistor value Switch and e-strike magnet set with alarm and tamper circuit R1 resistor in series and R2 resistor in parallel — xx=resistor value

N707AU/STER1xxR2xxR3xx

N707AU/STER1xxR3xx N707AU/STER1xxR2xxR3xxR4xx

EXAMPLE:

N707AU E=Strike set with alarm circuit 1K resistor in series, 1K resistor in parallel, and tamper circuit 1K resistor in series, 1 K resistor in parallel

N707AU/STER11KR21KR31KR41K

WOOD DOORS — NON FERROUS APPLICATIONS: Mount in desired location and orientation using #6 pan-head screws with a minimum recommended length of 1/2 inch. To ensure the highest security, keep the gap as small as practical. A 1/32” gap is recommended but the switch will operate at a maximum 1/8” gap. The flexible cable may exit the switch from either the left of the right side by removing the two #4 flathead machine screws located on the base of the switch and flipping the switch 180°. Refasten the screws but DO NOT OVERTIGHTEN THE SCREWS. After the switch and magnet have been mounted, remove the SWITCH BASE and temporarily mount the TAMPER INSERT, using the same #6 screws, in the same location that was used to mount the SWITCH BASE. Permanently mount the TAMPER INSERT using a third #6 screw in the location shown in the drawing. Remove the SWITCH BASE mounting screws and re-install the switch base over the TAMPER INSERT. The tamper circuit will alarm before the switch can be removed. STEEL DOOR AND FERROUS SURFACE APPLICATIONS : When mounting the switch and magnet on ferrous surfaces such as steel doors and safes, follow the above installation instructions, but you must also install the enclosed 1/4” thick spaces under the switch and magnet to achieve a 1/8” operate gap. Use #6 screws (stainless steel recommended) with a minimum recommended length of 1-1/2”. Use Spacer Kit (part number: N707AUSPKIT) for installation on offset surfaces to achieve correct alignment. INSTALLATION INSTRUCTIONS This level 2 BMS is to be connected / used with UL Listed Burglar Panels / Systems, Switch and Magnet must be aligned for corrrect operation!

Royne Industries LLC, dba Nascom | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 12009-15 Rev. 3

N200AU MIGHTY MITE OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

DESCRIPTION Nascom’s N200AU MIGHTY MITE is a mini overhead door switch with universal magnet for commercial and industrial overhead door applications. The MIGHTY MITE combines the installers’ choice of contact configuration with an N35 NdFeB magnet for maximum gap performance. The closed loop versions of the N200AU prevent false alarms caused by the side to side shifting of overhead doors with our unique NO DEAD SPOT ™ technology.

FEATURES • NO DEAD SPOT ™ TECHNOLOGY

• UNIVERSAL MOUNT

• EXTRA WIDE GAP - N35 NdFeB RARE EARTH MAGNET

• 36” 22AWG WIRE LEADS

• 24” ARMORED CABLE LEAD PROTECTION

• EXTRUDED ANODIZED (TYPE II) ALUMINUM

• LISTED TO UL634 STANDARD

ORDERING INFORMATION

CONTACT RATING (Max DC/Peak AC Resistive)

STATIC CONTACT RESISTANCE (50mV, 100mA)

PART NUMBER COLOR OPERATE GAP (in INCHES)

SWITCHING

CARRY

V

I

V

I

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N200AU/ST SILVER 1.75 to 2.75 DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N200AU/ST2CR SILVER 1.75 to 2.75 OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET: N200AU/STFB SILVER 1.50 to 2.50 30 VDC 0.2 Amps

200 VDC 0.5 Amps 10vA 1.5 Amps

150 mOhms

200 VDC 0.5 Amps 10vA 0.5 Amps

150 mOhms

3vA 0.5 Amps

100 mOhms

SINGLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N200AU/STSD SILVER 1.50 to 2.50 DOUBLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N200AU/STDD SILVER 1.50 to 2.50

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N200AU/STHS SILVER 0.1875 to 0.50 300 VDC 0.25 Amps

0.25 Amps

150 mOhms initial

10vA

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 120405-02 Rev. 1

N200AU MIGHTY MITE OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

WIRING SCHEMATIC

SWITCH CONTACT

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

OPEN LOOP, NORMALLY CLOSED CONTACT

DUAL CLOSED LOOP, NORMALLY OPEN CONTACTS

NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN) COMMON (BROWN)

NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN)

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

1.256 31.90

1.125 28.58

1.157 29.39

.812 20.62

.876 22.25

1.375 34.93

.406 10.31

2.645 67.18

Top View

2.188 55.58

2.300 58.42 2.000 50.80

End View

.380 9.65

Front View

Front View

SWITCH

MAGNET

INSTALLATION INSTRUCTIONS The switch can be mounted on the floor at the base of the door or on the wall at the top of the door. For best performance, align the switch and magnet housings and keep the gap distance between the switch and magnet as close as possible. FLOOR MOUNT: • With the overhead door closed, position the magnet on the lower right or left side of the door, then align the switch under the magnet. Adjust the position of the switch and magnet to ensure there is adequate clearance between the housings (1/4” minimum). • Make sure the stainless steel armored cable will not interfere with the door operation. • Mark the mounting hole locations for the switch and magnet. • Drill the marked locations on the door using a high speed drill adequately sized for self-tapping screws or machine screws. • Mount the magnet on the door. • Raise the door and drill the switch mounting hole locations using a masonry bit for concrete floors, sized to fit expansion anchors for #6 self-tapping screws. • Secure the switch to the floor. • Test the switch by attaching an ohm meter to the switch leads and operate the door. • Connect the leads to the alarm system conductors.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 1200405-02 Rev. 1

N200AU MIGHTY MITE OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

INSTALLATION INSTRUCTIONS, continued TOP MOUNT: •

With the overhead door closed, position the magnet at the top of the door in the desired location, then align the switch under the mag- net. Adjust the position of the switch and magnet to ensure there is adequate clearance between the housings (1/4” minimum). • Make sure the stainless steel armored cable will not interfere with the door operation. • Mark the mounting hole locations for the switch and magnet. • Drill the marked locations on the door using a high speed drill adequately sized for self-tapping screws or machine screws. • Drill the switch mounting hole locations using a masonry bit for concrete or cement block walls sized to fit expansion anchors for #6 self-tapping screws or use dry wall anchors for sheet rock walls. • Attach the switch to the wall first using #6 self-tapping screws and then attach the magnet to the door using #8 self-tapping screws. • Test the switch by attaching an ohm meter to the switch leads and operate the door. • Connect the leads to the alarm system conductors.

PART NUMBER SYSTEM

N200AU

XX XXX / XXXX X XX XXXXXXXX

PRODUCT TYPE (1 or 2 digits): • ST = SWITCH/MAGNET SET

END OF LINE RESISTOR (zero to 4 digits): • Blank = Resistor in series with the switch • P = Resistor in parallel with the switch • SP = Resistor 1 in series to the switch; resistor 2 in parallel to the switch

• SW = SWITCH ONLY • M = MAGNET ONLY

BUILT-IN END OF LINE RESISTOR VALUE (zero to 4 digits): • Blank = No built-in end of line resistor • All other resistor values are specified (e.g. 1K = 1,000 Ω)

CIRCUIT (0, 2 or 3 digits): • Blank = CLOSED LOOP • 2CR = DUAL CLOSED LOOP • FB = OPEN LOOP

• SD = SPDT • DD = DPDT • HS = HIGH SECURITY

LEAD LENGTH (zero, 3 or 4 digits): • Blank - 24 Inches • All other lengths specified in Inches with 3 digits (e.g. 036 = 36 Inches) * lead length is armored cable length- wire length is 12 inches greater than armored cable length

LEAD WIRE COLOR (zero to 2 digits): • Blank = Switch Color except:

» resistor contacts standard is red wire » all 2 conductor jacketed wire is grey

• BL = Blue leads • OL = Orange leads

WIRE TYPE (0 or 1 digit): • Blank = UL1061 | 22AWG | 7/30 • J = 2-conductor PVC Jacketed NEC Type CL2 and CM

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 1200405-02 Rev. 1

N205AU OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

DESCRIPTION Nascom’s N205AU is a wide gap standard size floor mount for commercial and industrial overhead door applications with a universal magnet. The N205AU combines the installers’ choice of contact configuration for maxi- mum gap performance. The closed loop versions of the N205AU prevent false alarms caused by the side to side shifting of overhead doors with our unique NO DEAD SPOT ™ technology.

FEATURES • NO DEAD SPOT ™ TECHNOLOGY

• UNIVERSAL MOUNT

• EXTRA WIDE GAP - N35 NdFeB RARE EARTH MAGNET

• 36” 22AWG WIRE LEADS

• 24” ARMORED CABLE LEAD PROTECTION

• EXTRUDED ANODIZED (TYPE II) ALUMINUM

• INDUSTRY STANDARD SWITCH MOUNTING HOLES

• LISTED TO UL634 STANDARD

ORDERING INFORMATION

CONTACT RATING (Max DC/Peak AC Resistive)

STATIC CONTACT RESISTANCE (50mV, 100mA)

PART NUMBER COLOR OPERATE GAP (in INCHES)

SWITCHING

CARRY

V

I

V

I

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N205AU/ST SILVER 2.00 to 3.50 DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N205AU/ST2CR SILVER 2.00 to 3.50 OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET: N205AU/STFB SILVER 1.75 to 3.00 30 VDC 0.2 Amps

200 VDC 0.5 Amps 10vA 1.5 Amps

150 mOhms

200 VDC 0.5 Amps 10vA 0.5 Amps

150 mOhms

3vA 0.5 Amps

100 mOhms

SINGLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N205AU/STSD SILVER 1.75 to 3.00 DOUBLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N205AU/STDD SILVER 1.75 to 3.00

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N205AU/STHS SILVER 0.1875 to 0.50 300 VDC 0.25 Amps

0.25 Amps

150 mOhms initial

10vA

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 120405-01 Rev. 2

N205AU OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

WIRING SCHEMATIC

SWITCH CONTACT

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

OPEN LOOP, NORMALLY CLOSED CONTACT

DUAL CLOSED LOOP, NORMALLY OPEN CONTACTS

NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN) COMMON (BROWN)

NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN)

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

2.125 53.98

.769 19.53

2.250 57.15

1.157 29.39

.876 22.25

1.375 34.93

.406 10.31

2.645 67.18

Top View

4.300 109.22

.380 9.65

4.000 101.60 4.300 109.22

End View

Front View

Front View

SWITCH

MAGNET

INSTALLATION INSTRUCTIONS The switch can be mounted on the floor at the base of the door or on the wall at the top of the door. For best performance, align the switch and magnet housings and keep the gap distance between the switch and magnet as close as possible. FLOOR MOUNT: • With the overhead door closed, position the magnet on the lower right or left side of the door, then align the switch under the magnet. Adjust the position of the switch and magnet to ensure there is adequate clearance between the housings (1/4” minimum). • Make sure the stainless steel armored cable will not interfere with the door operation. • Mark the mounting hole locations for the switch and magnet. • Drill the marked locations on the door using a high speed drill adequately sized for self-tapping screws or machine screws. • Mount the magnet on the door. • Raise the door and drill the switch mounting hole locations using a masonry bit for concrete floors, sized to fit expansion anchors for #6 self-tapping screws. • Secure the switch to the floor. • Test the switch by attaching an ohm meter to the switch leads and operate the door. • Connect the leads to the alarm system conductors.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 1200405-01 Rev. 1

N205AU OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

INSTALLATION INSTRUCTIONS, continued TOP MOUNT: •

With the overhead door closed, position the magnet at the top of the door in the desired location, then align the switch under the mag- net. Adjust the position of the switch and magnet to ensure there is adequate clearance between the housings (1/4” minimum). • Make sure the stainless steel armored cable will not interfere with the door operation. • Mark the mounting hole locations for the switch and magnet. • Drill the marked locations on the door using a high speed drill adequately sized for self-tapping screws or machine screws. • Drill the switch mounting hole locations using a masonry bit for concrete or cement block walls sized to fit expansion anchors for #6 self-tapping screws or use dry wall anchors for sheet rock walls. • Attach the switch to the wall first using #6 self-tapping screws and then attach the magnet to the door using #8 self-tapping screws. • Test the switch by attaching an ohm meter to the switch leads and operate the door. • Connect the leads to the alarm system conductors.

PART NUMBER SYSTEM

N205AU

XX XXX / XXXX X XX XXXXXXXX

PRODUCT TYPE (1 or 2 digits): • ST = SWITCH/MAGNET SET

END OF LINE RESISTOR (zero to 4 digits): • Blank = Resistor in series with the switch • P = Resistor in parallel with the switch • SP = Resistor 1 in series to the switch; resistor 2 in parallel to the switch

• SW = SWITCH ONLY • M = MAGNET ONLY

BUILT-IN END OF LINE RESISTOR VALUE (zero to 4 digits): • Blank = No built-in end of line resistor • All other resistor values are specified (e.g. 1K = 1,000 Ω)

CIRCUIT (0, 2 or 3 digits): • Blank = CLOSED LOOP • 2CR = DUAL CLOSED LOOP • FB = OPEN LOOP

• SD = SPDT • DD = DPDT • HS = HIGH SECURITY

LEAD LENGTH (zero, 3 or 4 digits): • Blank - 24 Inches • All other lengths specified in Inches with 3 digits (e.g. 036 = 36 Inches) * lead length is armored cable length- wire length is 12 inches greater than armored cable length

LEAD WIRE COLOR (zero to 2 digits): • Blank = Switch Color except:

» » resistor contacts standard is red wire » » all 2 conductor jacketed wire is grey

• BL = Blue leads • OL = Orange leads

WIRE TYPE (0 or 1 digit): • Blank = UL1061 | 22AWG | 7/30 • J = 2-conductor PVC Jacketed NEC Type CL2 and CM

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 1200405-01 Rev. 1

N205A OVERHEAD DOOR SWITCH WITH AN L SHAPE MAGNET

DESCRIPTION Nascom’s N205A is a wide gap standard size floor mount for commercial and industrial overhead door applications with an L shape magnet. The N205A combines the installers’ choice of contact configuration for maxi- mum gap performance with an L shape magnet. The closed loop versions of the N205A prevent false alarms caused by the side to side shifting of overhead doors with our unique NO DEAD SPOT ™ technol- ogy.

FEATURES • NO DEAD SPOT ™ TECHNOLOGY

• WIDE GAP - AlNiCo 5 MAGNET

• 24” ARMORED CABLE LEAD PROTECTION

• 36” 22AWG WIRE LEADS

• INDUSTRY STANDARD SWITCH MOUNTING HOLES

• EXTRUDED ANODIZED (TYPE II) ALUMINUM

• LISTED TO UL634 STANDARD

ORDERING INFORMATION

CONTACT RATING (Max DC/Peak AC Resistive)

STATIC CONTACT RESISTANCE (50mV, 100mA)

PART NUMBER COLOR OPERATE GAP (in INCHES)

SWITCHING

CARRY

V

I

V

I

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N205A/ST SILVER 1.50 to 2.50 DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N205A/ST2CR SILVER 1.50 to 2.50 OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET: N205A/STFB SILVER 1.25 to 2.25 30 VDC 0.2 Amps

200 VDC 0.5 Amps 10vA 1.5 Amps

150 mOhms

200 VDC 0.5 Amps 10vA 0.5 Amps

150 mOhms

3vA 0.5 Amps

100 mOhms

SINGLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N205A/STSD SILVER 1.25 to 2.25 DOUBLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N205A/STDD SILVER 1.75 to 3.00

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N205A/STHS SILVER 0.1875 to 0.50 300 VDC 0.25 Amps

0.25 Amps

150 mOhms initial

10vA

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 131112-01 Rev. 1

N205A OVERHEAD DOOR SWITCH WITH AN L SHAPE MAGNET

WIRING SCHEMATIC

SWITCH CONTACT

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

OPEN LOOP, NORMALLY CLOSED CONTACT

DUAL CLOSED LOOP, NORMALLY OPEN CONTACTS

NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN) COMMON (BROWN)

NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN)

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

1.400 35.56

2.250 57.15

2.118 53.80

.153

3.88

.370 9.40

.876 22.25

1.375 34.93

.260 6.60

1.300 33.02

Top View

3.750 95.25 3.850 97.79

4.300 109.22

End View

.380 9.65

Front View

Front View

SWITCH

MAGNET

INSTALLATION INSTRUCTIONS The switch can be mounted on the floor at the base of the door or on the wall at the top of the door. For best performance, align the switch and magnet housings and keep the gap distance between the switch and magnet as close as possible. FLOOR MOUNT: • With the overhead door closed, position the magnet on the lower right or left side of the door, then align the switch under the magnet. Adjust the position of the switch and magnet to ensure there is adequate clearance between the housings (1/4” minimum). • Make sure the stainless steel armored cable will not interfere with the door operation. • Mark the mounting hole locations for the switch and magnet. • Drill the marked locations on the door using a high speed drill adequately sized for self-tapping screws or machine screws. • Mount the magnet on the door. • Raise the door and drill the switch mounting hole locations using a masonry bit for concrete floors, sized to fit expansion anchors for #6 self-tapping screws. • Secure the switch to the floor. • Test the switch by attaching an ohm meter to the switch leads and operate the door. • Connect the leads to the alarm system conductors.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 131112-01 Rev. 1

N205A OVERHEAD DOOR SWITCH WITH AN L SHAPE MAGNET

PART NUMBER SYSTEM

N205A

XX XXX / XXXX X XX XXXXXXXX

PRODUCT TYPE (1 or 2 digits): • ST = SWITCH/MAGNET SET

END OF LINE RESISTOR (zero to 4 digits): • Blank = Resistor in series with the switch • P = Resistor in parallel with the switch • SP = Resistor 1 in series to the switch; resistor 2 in parallel to the switch

• SW = SWITCH ONLY • M = MAGNET ONLY

BUILT-IN END OF LINE RESISTOR VALUE (zero to 4 digits): • Blank = No built-in end of line resistor • All other resistor values are specified (e.g. 1K = 1,000 Ω)

CIRCUIT (0, 2 or 3 digits): • Blank = CLOSED LOOP • 2CR = DUAL CLOSED LOOP • FB = OPEN LOOP

• SD = SPDT • DD = DPDT • HS = HIGH SECURITY

LEAD LENGTH (zero, 3 or 4 digits): • Blank - 24 Inches • All other lengths specified in Inches with 3 digits (e.g. 036 = 36 Inches) * lead length is armored cable length- wire length is 12 inches greater than armored cable length

LEAD WIRE COLOR (zero to 2 digits): • Blank = Switch Color except:

» » resistor contacts standard is red wire » » all 2 conductor jacketed wire is grey

• BL = Blue leads • OL = Orange leads

WIRE TYPE (0 or 1 digit): • Blank = UL1061 | 22AWG | 7/30 • J = 2-conductor PVC Jacketed NEC Type CL2 and CM

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 131112-01 Rev. 1

N505AUTM 2 1/4” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

DESCRIPTION Nascom’s N505AUTM 2 1/4” TRACK MOUNT FLIP SWITCH TM with universal magnet handles commercial and industrial overhead door applications. The TRACK MOUNT FLIP SWITCH TM combines the installers’ choice of contact configuration with an N35 grade NdFeB magnet for maximum gap performance. The closed loop versions of the N505AUTM prevents false alarms caused by the up and down movement of overhead doors with our unique NO DEAD SPOT ™ technology. The switch can be mounted with the cable in either direction, without loss of gap.

FEATURES • NO DEAD SPOT ™ TECHNOLOGY

• EXTRUDED ANNODIZED (TYPE II) ALUMINUM

• QUICK SWITCH NSTALL - LESS THAN 60 SECONDS

• FLIP THE SWITCH - GAP IS NOT IMPACTED BY CABLE DIRECTION • 24” STAINLESS STEEL ARMORED CABLE LEAD PROTECTION

• UNIVERSAL MOUNT

• 36” 22AWG WIRE LEADS

• LISTED TO UL634 STANDARD

ORDERING INFORMATION

CONTACT RATING (Max DC/Peak AC Resistive)

STATIC CONTACT RESISTANCE (50mV, 100mA)

PART NUMBER COLOR OPERATE GAP (in INCHES)

SWITCHING

CARRY

V

I

V

I

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N505AUTM/ST SILVER 1.75 to 2.75 DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N505AUTM/ST2CR SILVER 1.75 to 2.75 OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET: N505AUTM/STFB SILVER 1.50 to 2.50 30 VDC 0.2 Amps

200 VDC 0.5 Amps 10vA 1.5 Amps

150 mOhms

200 VDC 0.5 Amps 10vA 0.5 Amps

150 mOhms

3vA 0.5 Amps

100 mOhms

SINGLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N505AUTM/STSD SILVER 1.50 to 2.50 DOUBLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N505AUTM/STDD SILVER 1.50 to 2.50

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 120405-04 Rev. 2

N505AUTM 2 1/4” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

WIRING SCHEMATIC - IN [mm]

SWITCH CONTACT

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

OPEN LOOP, NORMALLY CLOSED CONTACT

DUAL CLOSED LOOP, NORMALLY OPEN CONTACTS

NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN) COMMON (BROWN)

NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN)

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

3.000 76.20

3.000 76.20

3.313 84.15

2.883 73.23

3.120 79.25

2.880 73.15

SWITCH

MAGNET

1.922 48.82

2.071 52.60

SWITCH/MAGNET SET

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 1200405-04 Rev. 2

N505AUTM 2 1/4” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

INSTALLATION INSTRUCTIONS The N505AU Universal Track Mount switch and magnet system can be installed on either the right or left side of the overhead door. To change the direction of the direction of the armored cable, remove the 2 screws attaching the switch to the bracket and flip the switch. Insert and re-tighten the screws. Depending on the type of Roller Guide Track your door has, or operating condition of the door, it may be necessary to remove the rear half of the switch bracket to complete installation. • Un-pack the switch and magnet assemblies and set aside the magnet bracket assembly. • Slide the two halves of the switch bracket assembly apart so they are fully extended against the clamping screw. • Position the switch bracket assembly on the guide roller track in the desired location. Make sure the rear half of the bracket assembly is fully extended around the track. • Slide the bracket halves together on the track and hold the switch assembly in position. Carefully open and close the door to make sure the door will operate freely without contacting the switch or bracket assembly. ( If there is interference between the lower guide roller bracket plate and the switch bracket assembly, use the alternate mounting method below.) • Secure the switch and bracket assembly to the track by tightening the clamping screw on the side of the bracket. • With the door closed, align the magnet bracket assembly with the switch. Make sure there is sufficient clearance between the magnet and switch so the door can open and close freely. • Attach the magnet to the door using #6 self-tapping screws. • Connect an ohm meter to the switch leads and open and close the door to test switch for correct operation. • Connect the switch leads to the alarm system. Alternate Mounting Method: Use the alternate mounting method if your Roller guide track has a web that will not allow the the rear half of the switch bracket to wrap around the back of the roller guid track. Or if there is interference between the switch and bracket assembly and the lower guide roller bracket plate. • Remove the rear half of the mounting bracket by removing the clamping screw completely and separating the two halves of the bracket set. • Position the front half of the bracket with the switch on the rail in the desired location. Using the mounting holes in the side of the bracket as your guide, drill through the rail using a 3/16 drill in two locations. • To mount the bracket, use two pan head machine screws. ( Note : The screw heads must be on the inside of the rail to allow the door guide roller to pass ). From the inside of the rail, insert the screws through the holes in the rail and through the mounting holes in the side of the bracket. Place a washer over the screw and use a nylock type lock nut to secure the bracket to the rail. If nylock type nuts are not available use thread locking compound on the mounting screw threads. This will prevent the mounting screws from loosening due to vibration from the door opening and closing. • Open and close the door to make sure the door will operate freely without contacting the switch or mounting bracket. • With the door closed, re-align the magnet actuator with the switch. Make sure there is sufficient clearance between the magnet and switch so the door can open and close freely. • Connect an ohm meter to the switch leads and open and close the door to test the switch for correct operation. • Connect the switch leads to the alarm system.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 1200405-04 Rev. 2

N505AUTM 2 1/4” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

N505AUTM

XX XXX / XXXX X XX XXXXXXXX

PRODUCT TYPE (1 or 2 digits): • ST = SWITCH/MAGNET SET

END OF LINE RESISTOR (zero to 4 digits): • Blank = Resistor in series with the switch • P = Resistor in parallel with the switch • SP = Resistor 1 in series to the switch; resistor 2 in parallel to the switch

• SW = SWITCH ONLY • M = MAGNET ONLY

BUILT-IN END OF LINE RESISTOR VALUE (zero to 4 digits): • Blank = No built-in end of line resistor • All other resistor values are specified (e.g. 1K = 1,000 Ω)

CIRCUIT (0, 2 or 3 digits): • Blank = CLOSED LOOP • 2CR = DUAL CLOSED LOOP • FB = OPEN LOOP

• SD = SPDT • DD = DPDT

LEAD LENGTH (zero, 3 or 4 digits): • Blank - 24 Inches • All other lengths specified in Inches with 3 digits (e.g. 036 = 36 Inches) * lead length is armored cable length- wire length is 12 inches greater than armored cable length

LEAD WIRE COLOR (zero to 2 digits): • Blank = Switch Color except:

» » resistor contacts standard is red wire » » all 2 conductor jacketed wire is grey

• BL = Blue leads • OL = Orange leads

WIRE TYPE (0 or 1 digit): • Blank = UL1061 | 22AWG | 7/30 • J = 2-conductor PVC Jacketed NEC Type CL2 and CM

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 4 DWG No. 1200405-04 Rev. 2

N505AUTMC 3” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

DESCRIPTION Nascom’s N505AUTM 3” TRACK MOUNT FLIP SWITCH TM with universal magnet handles commercial and industrial overhead door applications. The TRACK MOUNT FLIP SWITCH TM combines the installers’ choice of contact configuration with an N35 grade NdFeB magnet for maximum gap performance. The closed loop versions of the N505AUTMC prevent false alarms caused by the up and down movement of overhead doors with our unique NO DEAD SPOT ™ technology. The switch can be mounted with the cable in either direction, without loss of gap.

FEATURES • NO DEAD SPOT ™ TECHNOLOGY

• EXTRUDED ANNODIZED (TYPE II) ALUMINUM

• QUICK SWITCH NSTALL - LESS THAN 60 SECONDS

• FLIP THE SWITCH - GAP IS NOT IMPACTED BY CABLE DIRECTION • 24” STAINLESS STEEL ARMORED CABLE LEAD PROTECTION

• UNIVERSAL MOUNT

• 36” 22AWG WIRE LEADS

• LISTED TO UL634 STANDARD

ORDERING INFORMATION

CONTACT RATING (Max DC/Peak AC Resistive)

STATIC CONTACT RESISTANCE (50mV, 100mA)

PART NUMBER

COLOR OPERATE GAP (in INCHES)

SWITCHING

CARRY

V

I

V

I

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N505AUTMC/ST SILVER 1.75 to 2.75 DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N505AUTMC/ST2CR SILVER 1.75 to 2.75 OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET: N505AUTMC/STFB SILVER 1.50 to 2.50 30 VDC 0.2 Amps

200 VDC 0.5 Amps 10vA 1.5 Amps

150 mOhms

200 VDC 0.5 Amps 10vA 0.5 Amps

150 mOhms

3vA 0.5 Amps

100 mOhms

SINGLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N505AUTMC/STSD SILVER 1.50 to 2.50 DOUBLE POLE DOUBLE THROW, SWITCH/MAGNET SET: N505AUTMC/STDD SILVER 1.50 to 2.50

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

30 VDC 0.2 Amps

3vA 0.5 Amps

100 mOhms

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 1 DWG No. 120405-05 Rev. 2

N505AUTMC 3” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

WIRING SCHEMATIC

SWITCH CONTACT

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

OPEN LOOP, NORMALLY CLOSED CONTACT

DUAL CLOSED LOOP, NORMALLY OPEN CONTACTS

NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN) COMMON (BROWN)

NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN)

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

3.000 76.20

3.000 76.20

3.313 84.15

4.013 101.93

2.880 73.15

3.120 79.25

SWITCH

MAGNET

1.922 48.82

2.556 64.92

SWITCH/MAGNET SET

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 1200405-05 Rev. 2

N505AUTMC 3” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

INSTALLATION INSTRUCTIONS The N505AU Universal Track Mount switch and magnet system can be installed on either the right or left side of the overhead door. To change the direction of the direction of the armored cable, remove the 2 screws attaching the switch to the bracket and flip the switch. Insert and re-tighten the screws. Depending on the type of Roller Guide Track your door has, or operating condition of the door, it may be necessary to remove the rear half of the switch bracket to complete installation. • Un-pack the switch and magnet assemblies and set aside the magnet bracket assembly. • Slide the two halves of the switch bracket assembly apart so they are fully extended against the clamping screw. • Position the switch bracket assembly on the guide roller track in the desired location. Make sure the rear half of the bracket assembly is fully extended around the track. • Slide the bracket halves together on the track and hold the switch assembly in position. Carefully open and close the door to make sure the door will operate freely without contacting the switch or bracket assembly. ( If there is interference between the lower guide roller bracket plate and the switch bracket assembly, use the alternate mounting method below.) • Secure the switch and bracket assembly to the track by tightening the clamping screw on the side of the bracket. • With the door closed, align the magnet bracket assembly with the switch. Make sure there is sufficient clearance between the magnet and switch so the door can open and close freely. • Attach the magnet to the door using #6 self-tapping screws. • Connect an ohm meter to the switch leads and open and close the door to test switch for correct operation. • Connect the switch leads to the alarm system. Alternate Mounting Method: Use the alternate mounting method if your Roller guide track has a web that will not allow the the rear half of the switch bracket to wrap around the back of the roller guid track. Or if there is interference between the switch and bracket assembly and the lower guide roller bracket plate. • Remove the rear half of the mounting bracket by removing the clamping screw completely and separating the two halves of the bracket set. • Position the front half of the bracket with the switch on the rail in the desired location. Using the mounting holes in the side of the bracket as your guide, drill through the rail using a 3/16 drill in two locations. • To mount the bracket, use two pan head machine screws. ( Note : The screw heads must be on the inside of the rail to allow the door guide roller to pass ). From the inside of the rail, insert the screws through the holes in the rail and through the mounting holes in the side of the bracket. Place a washer over the screw and use a nylock type lock nut to secure the bracket to the rail. If nylock type nuts are not available use thread locking compound on the mounting screw threads. This will prevent the mounting screws from loosening due to vibration from the door opening and closing. • Open and close the door to make sure the door will operate freely without contacting the switch or mounting bracket. • With the door closed, re-align the magnet actuator with the switch. Make sure there is sufficient clearance between the magnet and switch so the door can open and close freely. • Connect an ohm meter to the switch leads and open and close the door to test the switch for correct operation. • Connect the switch leads to the alarm system.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 3 DWG No. 1200405-05 Rev. 2

N505AUTMC 3” TRACK MOUNT FLIP SWITCH WITH UNIVERSAL MAGNET

N505AUTMC

XX XXX / XXXX X XX XXXXXXXX

PRODUCT TYPE (1 or 2 digits): • ST = SWITCH/MAGNET SET

END OF LINE RESISTOR (zero to 4 digits): • Blank = Resistor in series with the switch • P = Resistor in parallel with the switch • SP = Resistor 1 in series to the switch; resistor 2 in parallel to the switch

• SW = SWITCH ONLY • M = MAGNET ONLY

BUILT-IN END OF LINE RESISTOR VALUE (zero to 4 digits): • Blank = No built-in end of line resistor • All other resistor values are specified (e.g. 1K = 1,000 Ω)

CIRCUIT (0, 2 or 3 digits): • Blank = CLOSED LOOP • 2CR = DUAL CLOSED LOOP • FB = OPEN LOOP

• SD = SPDT • DD = DPDT

LEAD LENGTH (zero, 3 or 4 digits): • Blank - 24 Inches • All other lengths specified in Inches with 3 digits (e.g. 036 = 36 Inches) * lead length is armored cable length- wire length is 12 inches greater than armored cable length

LEAD WIRE COLOR (zero to 2 digits): • Blank = Switch Color except:

» » resistor contacts standard is red wire » » all 2 conductor jacketed wire is grey

• BL = Blue leads • OL = Orange leads

WIRE TYPE (0 or 1 digit): • Blank = UL1061 | 22AWG | 7/30 • J = 2-conductor PVC Jacketed NEC Type CL2 and CM

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 4 DWG No. 1200405-05 Rev. 2

N505ASCD SHORTY MITE CURTAIN DOOR SET

DESCRIPTION Nascom’s N505ASCD is a short, 2” block switch with an L bracket, designed for rollup or curtain doors. It combines the installers’ choice of contact con- figuration with an N35 NdFeB magnet for maximum gap performance. The N505ASCD prevents false alarms caused by warping or shifting of doors, and features our unique NO DEAD SPOT™ technology.

FEATURES • NO DEAD SPOT ™ TECHNOLOGY

• 24” ARMORED CABLE LEAD PROTECTION

• EXTRA WIDE GAP - N35 NdFeB RARE EARTH MAGNET

• 36” 22AWG WIRE LEADS

• PROTECTIVE WEAR PAD • LISTED TO UL634 STANDARD

• EXTRUDED ANODIZED (TYPE II) ALUMINUM

ORDERING INFORMATION

CONTACT RATING (Max DC/Peak AC Resistive)

STATIC CONTACT RESISTANCE (50mV, 100mA)

PART NUMBER COLOR OPERATE GAP (in INCHES)

SWITCHING

CARRY

V

I

V

I

CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N505ASCD/ST SILVER 1.50 to 2.50 DUAL CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET: N505ASCD/ST2CR SILVER 1.50 to 2.50

200 VDC 0.5 Amps 10vA 1.5 Amps

150 mOhms

200 VDC 0.5 Amps 10vA 0.5 Amps

150 mOhms

WIRING SCHEMATIC

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

107 DWG No. 140207-01 Rev.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com

N505ASCD SHORTY MITE CURTAIN DOOR SET

DIMENSIONS - IN [mm]

1.125 28.58

2.500 63.50

.625 15.88

1.625 41.28

1.625 41.28

1.125 28.58

1.125 28.58

1.125 28.58

FRONT VIEW END VIEW

END VIEW

FRONT VIEW

SWITCH

MAGNET

.125 3.18

.250 6.35

1.625 41.28

1.125 28.58

1.125 28.58

.750 19.05

1.125 28.58

3.000 76.20

END VIEW

FRONT VIEW

FRONT VIEW

SPACER

WEAR PAD

INSTALLATION INSTRUCTIONS • Lower the door to closed position. Make sure there are no obstructions to prevent complete closure of door. • Position magnet at the desired height on door with the end of magnet housing aligned with inside edge of the door track. Mark the position of magnet. • Clean the area on door where magnet is to be mounted with alcohol. • Remove the liner from the mounting tape on rear surface of magnet. Position the magnet where previously marked and press the magnet onto door. • Align the switch bracket assembly on the track with the magnet on door. The top edge of the magnet should align with the midpoint on the switch housing. Make sure the back of switch housing is seated against the edge of the track. • Using the slots in the bracket as a guide, drill two 5/32” holes in the track as close to the switch as possible. • Position the wear pad on the inside of the track and align the holes in the wear pad with the holes you just drilled. • Insert two #6X 5/8” screws thru the slots in the bracket and thru the holes drilled in track and into the holes in the wear pad. Tighten screws carefully until assembly is snug on the track. Do not over tighten the screws. • Use two #6X3/4” screws to mount the magnet if desired. • Open the door to its fully open position to make sure the magnet will clear the door stop at the top of the door and to make sure the Angle plate at the bottom of the door will clear the switch assembly. It may be necessary to notch the angle plate at the bottom of the door to allow clearance for the door to move freely past the switch assembly. • Connect the switch leads to an ohm meter and open and close the door to test switch for correct operation. • Connect the switch leads to the alarm system.

108 DWG No. 140207-01 Rev. 1

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com