NASCOM DATABOOK 2014
N282TXG SURFACE MOUNT EXTRA WIDE GAP SCREW TERMINAL SWITCH SET
WIRING SCHEMATIC
NC, OPEN LOOP (WHITE)
SWITCH CONTACT
SWITCH CONTACT
SPDT, SINGLE POLE DOUBLE THROW COMMON (BROWN) NO, CLOSED LOOP (RED)
CLOSED LOOP, NORMALLY OPEN CONTACT
OPEN LOOP, NORMALLY CLOSED CONTACT
DIMENSIONS - IN [mm]
TOP VIEW
TOP VIEW
2.600 66.04
2.090 53.09
.125 3.18
2.600 66.04
.575 14.61
FRONT VIEW
FRONT VIEW
.600 15.24
2.600 66.04
.575 14.61
RIGHT VIEW
RIGHT VIEW
.600 15.24
.600 15.24
SWITCH
MAGNET
SPACER
INSTALLATION INSTRUCTIONS Note: High Security model – Dots on switch and magnet must be aligned for correct operation.
• Remove the snap-on covers from the switch and magnet. • Position the switch on the door/window frame in the desired location as close to the movable part of the door /window as possible. • Mark the switch mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 self-tapping screws. • Install screws and tighten to mount the switch on the door/window frame. • Position the magnet on the movable part of the door/window, align the magnet with the switch as close as possible. For steel door or window applications, use the enclosed spacer under the magnet. • Mark the magnet mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 self-tapping screws. • Install screws and tighten to mount the magnet on the door/window. • Connect the alarm circuit leads to the terminals on the switch and test the system for correct operation. • Snap the covers on the switch and magnet.
Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 130212-01 Rev. 1
Made with FlippingBook