NASCOM DATABOOK 2014
N1178CT 3/4” RECESSED WIDE GAP STUBBY DOOR CONTACT SET
WIRING SCHEMATIC
SWITCH CONTACT
SWITCH CONTACT
CLOSED LOOP, NORMALLY OPEN CONTACT
OPEN LOOP, NORMALLY CLOSED CONTACT
DIMENSIONS - IN [mm]
.910
.910
23.11
23.11
TOP VIEW
.730
.730
18.54
18.54
TOP VIEW
.480
12.19
.480
12.19
FRONT VIEW
1.190 30.23
.660 16.76
.805 20.45
.435 11.05
FRONT VIEW
.435 11.05
.060 1.52
.060 1.52
SWITCH
MAGNET
INSTALLATION INSTRUCTIONS • Mark location for the switch on the door frame and mark the location for the magnet on the door. • Make sure switch and magnet hole locations are aligned.
• Drill holes for the switch and magnet using a 3/4” Hole Saw for steel doors or a Forstner bit for wood doors. • Press the magnet into the hole in the door until seated firmly against the head. Silicone may be used to secure the magnet in wood doors. • Connect the switch terminals to the alarm circuit conductors. Insert wire leads into hole followed by the switch and press the switch into the hole until the head is flush with the door frame. • Test switch for correct operation and make sure gap performance is acceptable.
Royne Industries LLC, dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 120119-02 Rev. 2
Made with FlippingBook