NASCOM DATABOOK 2014

N200AU MIGHTY MITE OVERHEAD DOOR SWITCH WITH UNIVERSAL MAGNET

WIRING SCHEMATIC

SWITCH CONTACT

SWITCH CONTACT

CLOSED LOOP, NORMALLY OPEN CONTACT

OPEN LOOP, NORMALLY CLOSED CONTACT

DUAL CLOSED LOOP, NORMALLY OPEN CONTACTS

NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN) COMMON (BROWN)

NC, OPEN LOOP (WHITE) NO, CLOSED LOOP (RED)

COMMON (BROWN)

DPDT, DOUBLE POLE DOUBLE THROW

SPDT, SINGLE POLE DOUBLE THROW

DIMENSIONS - IN [mm]

1.256 31.90

1.125 28.58

1.157 29.39

.812 20.62

.876 22.25

1.375 34.93

.406 10.31

2.645 67.18

Top View

2.188 55.58

2.300 58.42 2.000 50.80

End View

.380 9.65

Front View

Front View

SWITCH

MAGNET

INSTALLATION INSTRUCTIONS The switch can be mounted on the floor at the base of the door or on the wall at the top of the door. For best performance, align the switch and magnet housings and keep the gap distance between the switch and magnet as close as possible. FLOOR MOUNT: • With the overhead door closed, position the magnet on the lower right or left side of the door, then align the switch under the magnet. Adjust the position of the switch and magnet to ensure there is adequate clearance between the housings (1/4” minimum). • Make sure the stainless steel armored cable will not interfere with the door operation. • Mark the mounting hole locations for the switch and magnet. • Drill the marked locations on the door using a high speed drill adequately sized for self-tapping screws or machine screws. • Mount the magnet on the door. • Raise the door and drill the switch mounting hole locations using a masonry bit for concrete floors, sized to fit expansion anchors for #6 self-tapping screws. • Secure the switch to the floor. • Test the switch by attaching an ohm meter to the switch leads and operate the door. • Connect the leads to the alarm system conductors.

Royne Industries LLC dba NASCOM | P: 800.843.5530 | F: 800.727.4041 | www.nascominc.com 2 DWG No. 1200405-02 Rev. 1